The problem
Leaks are only found after the valve is fitted to the boiler and rework doubles the cost; three parts with different ports mean swapping fixtures all day; and hold time and pressure set by feel let one missed leak become a string of complaints.
Capability
Bench tests water-tightness of the inlet connector assembly, outlet connector assembly and antifreeze valve of combi boilers, one machine with three dedicated fixtures. Inlet/outlet connectors: purge the line for at least 5s, pressurise to 0.3MPa, hold 15s and judge by leakage. Antifreeze valve: purge at 0.1-0.2MPa for at least 5s and check initial sealing, then rotate the handle to "-" aligned with the arrow, raise slowly to 300kPa and hold 10s with no drainage for a pass, then continue to 380kPa where intermittent drainage is allowed to verify the relief function. Digital pressure gauge with 0.001MPa resolution, mechanical stopwatch, dedicated fixtures and stopper rod, start/stop buttons, compact bench for line stations.


Key specifications
- 用途:进水接头组件、出水接头组件、防冻阀组件水密性检测(三部件一机全测)
- 进/出水接头测试:排空≥5s后加压0.3MPa,保压15s观察渗漏判定
- 防冻阀密封测试:0.1~0.2MPa低压排气≥5s查初始密封→300kPa保压10s无排水合格
- 防冻阀泄压测试:380kPa允许断续排水,验证开启泄压功能
- 压力显示:数字压力表实时显示(0.001MPa分辨率);机械秒表计时
- 工装:三部件专用夹具+堵水棒;旋转手柄"-"位对齐箭头操作
- 操作:启动/停止按钮,单人单工位;结构紧凑适合产线
Applications
Factory sealing inspection of combi-boiler water-circuit parts; leak sampling of antifreeze valves and connector fittings; incoming and type testing of heating-circuit parts; relief-opening pressure calibration in R&D
About the manufacturer
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and lifetime technical service; 12-month warranty and lifetime spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.