The problem

A ceramic-cartridge faucet faces several very different checks at once: mechanical strength under water pressure up to 1.6MPa and beyond, sealing at both dynamic and static pressure, flow values at 0.1MPa, and the sensitivity actuation point. Spreading these across separate single-function benches means reloading the sample again and again, and hot-cold data never lines up.

Capability

Two stations divide the work: one combines faucet flow testing with sensitivity testing, while the other independently runs sealing and strength tests on faucets, hoses or showers, so neither waits for the other. A dual-path water supply serves both: the low-pressure path handles dynamic testing at 0.3-0.8MPa (accuracy class 1, manually regulated, 0-99.9 s) and the high-pressure path handles static testing at 1.0-5.0MPa (accuracy class 1, inverter-regulated with automatic pressure tracking, 0-999.9 s), fed by a stainless multi-stage centrifugal pump plus a plunger pump with a maximum of 6MPa. The cycling routine is programmable, for example 0.5MPa dynamic for 2 s followed by 0.4MPa static for 2 s, with times and cycle counts set on the HMI. Hot-cold alternation covers 15-85degC +/-2degC with independent hot and cold timing, a stepper-motor changeover valve switching automatically, a 2P compressor for cooling and heaters for the hot side, and two 60 L insulated stainless tanks. PT100 sensors read temperature to 0.1degC; water temperature, pressure and flow are plotted live, and out-of-range values stop the test, raise an alarm and record the failure time with the function data at that moment. Power-fail memory keeps the count and state, resuming where it stopped. A Mitsubishi FX-series PLC, Weinview HMI and Mitsubishi inverter run the system, the test area is guarded by an acrylic shield, and the whole water circuit is stainless steel.

NL test equipment

NL test equipment

Key specifications

  • Application: mechanical strength, sealing, flow and sensitivity testing of ceramic-cartridge faucets
  • Stations: 2 - flow/sensitivity station plus sealing/strength station
  • Dynamic pressure: 0.3-0.8MPa, class 1, manual regulation, 0-99.9 s
  • Static pressure: 1.0-5.0MPa, class 1, inverter-regulated auto tracking, 0-999.9 s
  • Maximum supply pressure: 6MPa (multi-stage centrifugal + plunger pumps)
  • Cycle program: 0.5MPa dynamic 2 s then 0.4MPa static 2 s, times and counts settable
  • Water temperature: 15-85degC +/-2degC, hot-cold alternation with independent timing
  • Changeover: stepper-motor valve, 2P compressor cooling and electric heating
  • Tanks: two 60 L insulated stainless tanks (hot and cold)
  • Sensors: PT100, accuracy 0.1degC
  • Control: Mitsubishi FX-series PLC, Weinview HMI, 3kW Mitsubishi inverter
  • Data: live temperature/pressure/flow curves, alarm and failure-time recording, power-fail resume

Applications

Factory inspection and type testing at faucet plants; incoming and supplier-audit sampling by sanitary brands; third-party ceramic-cartridge faucet testing; sealing-strength validation of cartridges, hoses and shower sets

About the manufacturer

Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.

相关分类

地址:中山市小榄镇民安中路163号民安广场1幢25楼25G 联系人:张总 电话:400 000 8722 微信 baxi188699386

机械行业网站 粤ICP备2025387148号-2 网站地图
免责声明:本站只起到信息平台作用,不为交易经过负任何责任,请双方谨慎交易,以确保您的权益。
内容的真实性、准确性和合法性由发布企业或个人负责。如有信息、图片侵权,请及时联系我们处理。
友情提醒:投资有风险 加盟需谨慎